using System;
using System.Collections.Generic;
using System.Linq;
using System.Threading;
using System.Threading.Tasks;
using Microsoft.Extensions.Hosting;
using Microsoft.Extensions.Logging;
using S7.Net;
using PMSWPF.Models;
using PMSWPF.Enums;
using PMSWPF.Helper;
namespace PMSWPF.Services
{
public class S7BackgroundService : BackgroundService
{
private readonly ILogger<S7BackgroundService> _logger;
private readonly DataServices _dataServices;
private readonly Dictionary<int, Plc> _s7PlcClients = new Dictionary<int, Plc>();
private readonly TimeSpan _pollingInterval = TimeSpan.FromSeconds(1); // 轮询间隔
private List<Device>? _s7Devices;
public S7BackgroundService(ILogger<S7BackgroundService> logger, DataServices dataServices)
{
_logger = logger;
_dataServices = dataServices;
_dataServices.OnDeviceListChanged += HandleDeviceListChanged;
}
private void HandleDeviceListChanged(List<Device> devices)
{
_s7Devices = devices.Where(d => d.ProtocolType == ProtocolType.S7 && d.IsActive)
.ToList();
// 当设备列表变化时更新PLC客户端
// 这里需要更复杂的逻辑来处理连接的关闭和新连接的建立
// 简单起见,这里只做日志记录
_logger.LogInformation("Device list changed. S7 clients might need to be reinitialized.");
}
protected override async Task ExecuteAsync(CancellationToken stoppingToken)
{
_logger.LogInformation("S7 Background Service is starting.");
stoppingToken.Register(() => _logger.LogInformation("S7 Background Service is stopping."));
_s7Devices = _dataServices.Devices?.Where(d => d.ProtocolType == ProtocolType.S7 && d.IsActive)
.ToList();
while (!stoppingToken.IsCancellationRequested)
{
_logger.LogDebug("S7 Background Service is doing background work.");
await PollS7Devices(stoppingToken);
try
{
await Task.Delay(_pollingInterval, stoppingToken);
}
catch (TaskCanceledException)
{
// When the stopping token is canceled, a TaskCanceledException is thrown.
// We should catch it to exit gracefully.
}
}
_logger.LogInformation("S7 Background Service has stopped.");
}
private async Task PollS7Devices(CancellationToken stoppingToken)
{
if (_s7Devices == null || !_s7Devices.Any())
{
_logger.LogDebug("No active S7 devices found to poll.");
return;
}
foreach (var device in _s7Devices)
{
if (stoppingToken.IsCancellationRequested) return;
if (!_s7PlcClients.ContainsKey(device.Id))
{
// Initialize Plc client for the device
try
{
var plc = new Plc(device.CpuType, device.Ip, (short)device.Prot, device.Rack, device.Slot);
await plc.OpenAsync();
_s7PlcClients[device.Id] = plc;
_logger.LogInformation($"Connected to S7 PLC: {device.Name} ({device.Ip})");
}
catch (Exception ex)
{
_logger.LogError(ex, $"Failed to connect to S7 PLC: {device.Name} ({device.Ip})");
continue;
}
}
var plcClient = _s7PlcClients[device.Id];
if (!plcClient.IsConnected)
{
try
{
await plcClient.OpenAsync();
_logger.LogInformation($"Reconnected to S7 PLC: {device.Name} ({device.Ip})");
}
catch (Exception ex)
{
_logger.LogError(ex, $"Failed to reconnect to S7 PLC: {device.Name} ({device.Ip})");
continue;
}
}
// Filter variables for the current device and S7 protocol
var s7VariablesTemp = device
.VariableTables.Where(vd => vd.ProtocolType == ProtocolType.S7 && vd.IsActive)
.ToList();
var s7Variables = s7VariablesTemp.SelectMany(vt => vt.DataVariables)
.ToList();
// ?.SelectMany(vt => vt.DataVariables)
if (s7Variables == null || !s7Variables.Any())
{
_logger.LogDebug($"No active S7 variables found for device: {device.Name}");
continue;
}
// Batch read variables
var addressesToRead = s7Variables.Select(vd => vd.S7Address)
.ToList();
if (!addressesToRead.Any()) continue;
try
{
// S7.Net.Plus library supports ReadMultiple, but it's more complex for different data types.
// For simplicity, we'll read them one by one for now, or use a more advanced batch read if all are same type.
// A more robust solution would involve grouping by data block and type.
// Example of reading multiple items (assuming all are of type DWord for simplicity)
// This part needs to be refined based on actual variable types and addresses
// var dataItems = addressesToRead.Select(addr => new DataItem { DataType = DataType.DataBlock, VarType = VarType.DWord, StringLength = 1, DB = 1, StartByteAdr = 0 }).ToList();
// plcClient.ReadMultiple(dataItems);
foreach (var variable in s7Variables)
{
if (stoppingToken.IsCancellationRequested) return;
try
{
// This is a simplified read. In a real scenario, you'd parse S7Address
// to get DataType, DB, StartByteAdr, BitAdr, etc.
// For now, assuming S7Address is directly readable by Read method (e.g., "DB1.DBW0")
var value = await plcClient.ReadAsync(variable.S7Address);
if (value != null)
{
// Update the variable's DataValue and DisplayValue
variable.DataValue = value.ToString();
variable.DisplayValue
= SiemensHelper.ConvertS7Value(value, variable.DataType, variable.Converstion);
_logger.LogDebug($"Read {variable.Name}: {variable.DataValue}");
}
}
catch (Exception ex)
{
_logger.LogError(ex, $"Failed to read variable {variable.Name} from {device.Name}");
}
}
}
catch (Exception ex)
{
_logger.LogError(ex, $"Error during batch read for device {device.Name}");
}
}
}
public override async Task StopAsync(CancellationToken stoppingToken)
{
_logger.LogInformation("S7 Background Service is stopping.");
// Close all active PLC connections
foreach (var plcClient in _s7PlcClients.Values)
{
if (plcClient.IsConnected)
{
plcClient.Close();
_logger.LogInformation($"Closed S7 PLC connection: {plcClient.IP}");
}
}
_s7PlcClients.Clear();
await base.StopAsync(stoppingToken);
}
}
}